7 resultados para early neonatal sepsis

em Aston University Research Archive


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fathers in the United Kingdom (UK) usually attend the birth and immediate care of their baby. They also have an increasing presence during complicated and preterm childbirth, newborn resuscitation and early neonatal unit(NNU) care. However, there is limited evidence about the effect of these experiences on them. The aim of this study was to gain an understanding of the experiences of fathers encountering these situations. The study consisted of three phases and was undertaken in one National Health Service trust in the UK. Qualitative semi-structured interviews using a phenomenological approach were undertaken with 20 first-time fathers present at the delivery, resuscitation and/or admission of their baby to the NNU. Direct observations were made of 22 normal and complicated deliveries and initial newborn care and qualitative semi-structured interviews using the critical incident approach were undertaken with 37 health care professionals (HCPs). The study generated qualitative and quantitative data that were analysed accordingly. The findings show that most fathers were involved for at least some of the time and often spontaneously initiated their involvement. Their most important need was for information. They were usually more concerned about their partner, irrespective of the baby?s need for resuscitation and NNU care. To facilitate their involvement, fathers needed guidance and support from HCPs, particularly delivery suite midwives. Most HCPs recognised the needs of fathers and ways in which they could be helped to connect with their experience. However, these needs were not always met, usually because of inadequate staffing levels, a lack of resources or a mother-centred philosophy of care. The findings suggest the service often determines the extent to which fathers are involved. It is anticipated that these findings will inform HCP education and training and the development of both policy and health education thereby enhancing the quality of care provision for fathers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to devise a scoring system that could aid in predicting neurologic outcome at the onset of neonatal seizures. METHODS: A total of 106 newborns who had neonatal seizures and were consecutively admitted to the NICU of the University of Parma from January 1999 through December 2004 were prospectively followed-up, and neurologic outcome was assessed at 24 months’ postconceptional age. We conducted a retrospective analysis on this cohort to identify variables that were significantly related to adverse outcome and to develop a scoring system that could provide early prognostic indications. RESULTS: A total of 70 (66%) of 106 infants had an adverse neurologic outcome. Six variables were identified as the most important independent risk factors for adverse outcome and were used to construct a scoring system: birth weight, Apgar score at 1 minute, neurologic examination at seizure onset, cerebral ultrasound, efficacy of anticonvulsant therapy, and presence of neonatal status epilepticus. Each variable was scored from 0 to 3 to represent the range from “normal” to “severely abnormal.” A total composite score was computed by addition of the raw scores of the 6 variables. This score ranged from 0 to 12. A cutoff score of =4 provided the greatest sensitivity and specificity. CONCLUSIONS: This scoring system may offer an easy, rapid, and reliable prognostic indicator of neurologic outcome after the onset of neonatal seizures. A final assessment of the validity of this score in routine clinical practice will require independent validation in other centers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Development of the cerebral cortex is influenced by sensory experience during distinct phases of postnatal development known as critical periods. Disruption of experience during a critical period produces neurons that lack specificity for particular stimulus features, such as location in the somatosensory system. Synaptic plasticity is the agent by which sensory experience affects cortical development. Here, we describe, in mice, a developmental critical period that affects plasticity itself. Transient neonatal disruption of signaling via the C-terminal domain of "disrupted in schizophrenia 1" (DISC1)-a molecule implicated in psychiatric disorders-resulted in a lack of long-term potentiation (LTP) (persistent strengthening of synapses) and experience-dependent potentiation in adulthood. Long-term depression (LTD) (selective weakening of specific sets of synapses) and reversal of LTD were present, although impaired, in adolescence and absent in adulthood. These changes may form the basis for the cognitive deficits associated with mutations in DISC1 and the delayed onset of a range of psychiatric symptoms in late adolescence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sepsis continues to be a major cause of morbidity and mortality as it can readily lead tosevere sepsis, septic shock, multiple organ failure and death. The onset can be rapid and difficult to define clinically. Despite the numerous candidate markers proposed in the literature, to date a serum marker for sepsis has not been found. The aim of this study was to assay the serum of clinically diagnosed patients with eithera Gram-negative or Gram- positive bacterial sepsis for elevated levels of nine potentialmarkers of sepsis, using commercially produced enzyme linked immunosorbent assays(ELISA). The purpose was to find a test marker for sepsis that would be helpful toclinicians in cases of uncertain sepsis and consequently expose false positive BC'scaused by skin or environmental contaminants. Nine test markers were assayed including IL-6, IL-I 0, ILI2, TNF-α, lipopolysaccharide binding protein, procalcitonin, sE-selectin, sICAM -1 and a potential differential marker for Gram-positive sepsis- anti-lipid S antibody. A total of 445 patients were enrolled into this study from the Queen Elizabeth Hospital and Selly Oak Hospital (Birmingham). The results showed that all the markers were elevated in patients with sepsis and that patients with a Gram-negative sepsis consistently produced higher median/range serum levels than those with a Gram-positive sepsis. No single marker was able to identify all the septic patients. Combining two markers caused the sensitivities and specificities for a diagnosis of sepsis to increase to within a 90% to 100% range. By a process of elimination the markers that survived into the last phase were IL-6 with sICAM -1, and anti-lipid S IgG assays Defining cut-off levels for a diagnosis of sepsis became problematic and a semi-blind trial was devised to test the markers in the absence of both clinical details and positive blood cultures. Patients with pyrexia of unknown origin and negative BC were included in this phase (4). The results showed that IL-6 with sICAM-l are authentic markers of sepsis. There was 82% agreement between the test marker diagnosis and the clinical diagnosis for sepsis in patients with a Gram-positive BC and 78% agreement in cases of Gram-negative Be. In the PUO group the test markers identified 12 cases of sepsis and the clinical diagnosis 15. The markers were shown to differentiate between early sepsis and sepsis, inflammatory responses and infection. Anti-lipid S with IL-6 proved be a sensitive marker for Gram-positive infections/sepsis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The coagulase-negative staphylococci are the most frequent cause of sepsis associated with indwelling intravascular catheters. Current microbiological investigations to support the diagnosis of catheter-related sepsis (CRS) include the culture of blood and catheter tips, however positive results may reflect specimen contamination, or colonisation of the catheter rather than true sepsis. Previous serological approaches to assist in the diagnosis of CRS based on cellular staphylococcal antigens have been of limited value. In this current study, the serodiagnostic potential of an exocellular antigen produced by 7 strains of coagulase-negative staphylococci cultured in brain heart infusion broth was investigated. Antigenic material isolated by gel permeation from liquid culture was characterised by immunological techniques and chemical analysis. Characterisation of the exocellular antigen revealed a novel glycerophosphoglycolipid, termed lipid S. which shared antigenic determinants with lipoteichoic acid, but differed by comprising a glycerophosphate chain length of only 6 units. In addition, lipid S was immunologically distinct from diphosphatidyl glycerol, a constituent cell membrane phospho lipid. An indirect enzyme linked immunosorbent assay (ELISA) based on lipid S was subsequently developed and used to determine serum antibody levels (IgM and IgG) in 67 patients with CRS due to staphylococci, and 67 patients with a central venous catheter (CVC) in situ who exhibited no evidence of sepsis. The sensitivity and specificity of the lipid S IgG ELISA was 75% and 90% respectively whilst the IgM assay had sensitivity and specificity of 52% and 85%. The addition of GullSORereagent to the EL1SA procedure to remove competing serum IgG and rheumatoid factor did not significantly improve the performance of the IgM assay. The serological response in serial serum samples of 13 patients with CRS due to staphylococci was investigated. Elevated levels of antibody were detected at an early stage of infection, prior to the isolation of microorganisms by standard culture methods, and before the clinical presentation of sepsis in 3 patients. The lipid S ELISA was later optimised and a rapid 4-hour assay developed for the serodiagnosis of CRS. Serum IgG levels were determined in 40 patients with CRS due to staphylococci and 40 patients with a CVC in situ who exhibited no evidence of sepsis. The sensitivity and specificity of the rapid IgG assay was 70% and 100% respectively. Elevated serum antibody levels in patients with endocarditis, prosthetic joint infection and pyogenic spondylodiscitis due to Gram-positive cocci were also detected with the lipid S ELISA suggesting that the assay may facilitate the diagnosis of these infections. Unexpected increased levels of anti-lipid S IgG in 31% of control patients with sciatica suggested a possible microbial aetiology of this condition. Further investigation of some of these patients by culture of microdiscectomy tissue removed at operation, revealed the presence of low-virulent microorganisms in 37% of patients of which Propionibacterium aeries accounted for 85% of the positive culture isolates. The results suggested a previously unrecognised association between P. acnes and sciatica, which may have implications for the future management of the condition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The recent withdrawal of a targeted sepsis therapy has diminished pharmaceutical enthusiasm for developing novel drugs for the treatment of sepsis. Angiopoietin-2 is an endothelial-derived protein that potentiates vascular inflammation and leakage and may be involved in sepsis pathogenesis. We screened approved compounds for putative inhibitors of angiopoietin-2 production and investigated underlying molecular mechanisms. Design: Laboratory and animal research plus prospective placebo-controlled randomized controlled trial (NCT00529139) and retrospective analysis (NCT00676897). Setting: Research laboratories of Hannover Medical School and Harvard Medical School. Patients: Septic patients/C57Bl/6 mice and human endothelial cells. Interventions: Food and Drug Administration-approved library screening. Measurements and Main Results: In a cell-based screen of more than 650 Food and Drug Administration-approved compounds, we identified multiple members of the 3-hydroxy-3-methyl-glutaryl-CoA reductase inhibitor drug class (referred to as statins) that suppressed angiopoietin-2. Simvastatin inhibited 3-hydroxy-3-methyl-glutaryl-CoA reductase, which in turn activated PI3K-kinase. Downstream of this signaling, PI3K-dependent phosphorylation of the transcription factor Foxo1 at key amino acids inhibited its ability to shuttle to the nucleus and bind cis-elements in the angiopoietin-2 promoter. In septic mice, transient inhibition of angiopoietin-2 expression by liposomal siRNA in vivo improved absolute survival by 50%. Simvastatin had a similar effect, but the combination of angiopoietin-2 siRNA and simvastatin showed no additive benefit. To verify the link between statins and angiopoietin-2 in humans, we performed a pilot matched case-control study and a small randomized placebo-controlled trial demonstrating beneficial effects on angiopoietin-2. Conclusions: 3-hydroxy-3-methyl-glutaryl-CoA reductase inhibitors may operate through a novel Foxo1-angiopoietin-2 mechanism to suppress de novo production of angiopoietin-2 and thereby ameliorate manifestations of sepsis. Given angiopoietin-2's dual role as a biomarker and candidate disease mediator, early serum angiopoietin-2 measurement may serve as a stratification tool for future trials of drugs targeting vascular leakage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hospitals can experience difficulty in detecting and responding to early signs of patient deterioration leading to late intensive care referrals, excess mortality and morbidity, and increased hospital costs. Our study aims to explore potential indicators of physiological deterioration by the analysis of vital-signs. The dataset used comprises heart rate (HR) measurements from MIMIC II waveform database, taken from six patients admitted to the Intensive Care Unit (ICU) and diagnosed with severe sepsis. Different indicators were considered: 1) generic early warning indicators used in ecosystems analysis (autocorrelation at-1-lag (ACF1), standard deviation (SD), skewness, kurtosis and heteroskedasticity) and 2) entropy analysis (kernel entropy and multi scale entropy). Our preliminary findings suggest that when a critical transition is approaching, the equilibrium state changes what is visible in the ACF1 and SD values, but also by the analysis of the entropy. Entropy allows to characterize the complexity of the time series during the hospital stay and can be used as an indicator of regime shifts in a patient’s condition. One of the main problems is its dependency of the scale used. Our results demonstrate that different entropy scales should be used depending of the level of entropy verified.